Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8538713

- Product Categories
- Friendly Links
Information Name: | Supply proof electromagnetic pulse valve |
Published: | 2011-09-13 |
Validity: | 30 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Electromagnetic pulse electromagnetic pulse valve diaphragm valve into the before and after the two chambers, when connected to the compressed air through the orifice into the room the day after tomorrow, then after the chamber pressure to close diaphragm valve output, pulse valve is "off" state. Pulse jet control instrument signal disappeared, pulse solenoid valve armature reset, put the chamber after stomatal closure, after the chamber pressure increases the diaphragm close to the valve outlet, electromagnetic pulse valve and in the "off" state. Pulse solenoid valve according to the import and export point of view and form the inlet can be divided into three types: a) rectangular electromagnetic pulse valve: the valve body at right angles to the import and export, directly controlled by the signal pulse valve; b) straight-through pulse solenoid valve: the import and export into the body 180 degrees, directly controlled by the signal pulse valve; c) submerged electromagnetic pulse valve: body submerged in the inlet air bag, directly under the control of the pulse signal solenoid valve. Electromagnetic pulse valve technology features: 1, the product of the working pressure is 0.1MPa ~ 0.7MPa, after degreasing medium is, in addition to water the air. 2, the nominal air pressure in the product state, the solenoid valve rated working voltage of 85%, the pulse valve opening response time should be less than 0.03s. 3, the working gas supply pressure is 0.1MPa, they can make the pulse valve is closed. 4, the product should be able to withstand the air pressure 0.8MPa. 5, the required environmental conditions, the electromagnetic coil of the shell of the insulation resistance should be greater than 1MΩ. 6, at room temperature of 5 degrees to 35 degrees, relative humidity of not more than 85% under the conditions of the electromagnetic coil of the shell can withstand 50Hz, 250V voltage for 1min, no breakdown. 7, pulse frequency of the electromagnetic valve to withstand 20Hz, all amplitude is 2mm, which lasted 30min after the vibration should be able to work properly. 8, in normal use conditions, the electromagnetic pulse valve diaphragm should total more than 80 million times the service life. |
Admin>>>
You are the 10015 visitor
Copyright © GuangDong ICP No. 10089450, Botou Tianjie Environmental Protection Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10015 visitor
Copyright © GuangDong ICP No. 10089450, Botou Tianjie Environmental Protection Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility